Twin And Earth Cable

Twin And Earth Cable

  • No.: Twin And Earth Cable
  • Brand: AMPXL/OEM
  • Conductor Material: Class 1 solid copper; Class 2 stranded copper
  • Conductor Diameter:
  • AWG:
  • Certification: CE, ROHS, UL, CCC
  • Insulation Material: PVC
  • Insulation Diameter:
  • Rip cord:
  • Jacket: PVC
  • Color: Customized
Close
Leave a Message We will call you back soon!
Email:ampxl@ampxl.com

Product Description


Twin And Earth Cable


 

Application:



Cable Standards:

This cable has a bare protective conductor
plus 1, 2 or 3 cores.
Used for fixed installations in dry or
damp premises clipped direct to surface,
on trays or in free air.
Where mechanical protection is required,
it can be laid in conduit or trunking.



BSEN 50363-3, BS 6004



Flame Retardant according to IEC/EN 60332-1-2









































Product Description:

Conductor

RE: 1mm² to 2.5mm²: Class 1 solid copper

RM: 4mm² to 16mm²: Class 2 stranded copper

Circuit Protection
Conductor (Earth)

1mm² to 2.5mm²: Class 1 solid copper

4mm² to 16mm²: Class 2 stranded copper

Insulation

Polyvinyl Chloride (PVC)

Sheath

Polyvinyl Chloride (PVC)


Characteristics:

Voltage Rating Uo/U

300/500V

Temperature Rating

-5°C to +70°C

Minimum Bending Radius

Fixed: 6 x overall diameter


Core Identification:
























Brown








































Brown



Blue





































Brown



Blue





































Brown



Blue



Black



































      Should not be installed at temperatures below 0°C or above +60°C





















































































































Dimensions:

No. Of
Cores

Nominal Cross Sectional Area(mm²)

Nominal Thickness
Of Insulation
(mm)

Nominal overall
diameter
(mm)

Nominal overall
diameter
(mm)

Nominal overall
diameter
(mm)

Nominal overall
diameter
(mm)

Nominal
Weight
Kg/km

2

1

1

1

0.6

0.9

4.35 x 7.95

68

2

1.5

1

1

0.7

0.9

4.85 x 8.90

87

2

2.5

1

1.5

0.8

1

5.65 x 10.65

120

2

4

2

1.5

0.8

1

6.30x 11.95

172

2

6

2

2.5

0.8

1.1

7.10x 13.70

235

2

10

2

4*

1

1.2

8.70x 17.25

373

2

16

2

6*

1

1.3

9.85 x 20.0

530

3

1

1

1

0,6

0.9

4.35 x 9.80

91

3

1.5

1

1

0.7

0.9

4.85 x 11.2

115
























Conductors:

Nominal Cross Sectional Area
(mm²)

MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km



Plain Wires



1

18.1



1.5

12.1



2.5

7.41


























Class 2 Stranded Conductors for Single Core and Multi-Core Cables

Nominal Cross Sectional Area  (mm²)

Current Carrying Capacity Amps

MAXIMUM RESISTANCE OF CONDUCTOR AT 20ºC
ohms/km

Annealed Copper Conductor

Circular

Plain Wires

4

7

4.61


6

7

3.08


10

7

1.83


16

7

1.15


        The above table is in accordance with EN 60228


Tel
Email
Map