LSZH Control Cable Shielded 2

LSZH Control Cable Shielded 2

  • No.: LSZH Control Cable Shielded 2
  • Brand: AMPXL/OEM
  • Conductor Material:
  • Conductor Diameter:
  • AWG:
  • Certification: CE, ROHS, UL, CCC
  • Insulation Material:
  • Insulation Diameter:
  • Rip cord:
  • Jacket:
  • Color: Customized
Close
Leave a Message We will call you back soon!
Email:ampxl@ampxl.com

    LSZH Control Cable Shielded 2


 

Application:



Cable Standards:

    control cable is used as a control cable in areas requiring light mechanical protection and areas where there is risk to life from fire,
smoke emissions and toxic fumes. The cables are designed to be used as a connecting cable for measuring, control and regulation equipment for assembly, production lines and conveyor    stems.



VDE 0207-303-7,
Flame Retardant according to IEC/EN 60332-1-2,
IEC/EN 60332-3-24
Low Smoke Zero Halogen according to IEC/EN 60754-1/2,
IEC/EN 61034-1/2






Product Description:

Conductor

Plain Annealed Stranded Copper

Insulation

LSZH insulated

Armouring

Galvanised Steel Wire Braid

Sheath

LSZH insulated


Characteristics:

Voltage Rating Uo/U

300/500V

Temperature Rating

Fixed: -40°C to +80°C

Flexed: -15°C to +70°C

Minimum Bending Radius

Fixed: 6 x overall diameter

Flexed: 15 x overall diameter


Core Identification:

3 Core and above


Black with


White numbers











































Numbers plus



Green/Yellow













Also available with coloured cores as follows:

3 Core:


Blue



Brown




Green/Yellow





































4 Core:


Brown



Black



Grey




Green/Yellow











Should not be installed at temperatures below -5℃












































































































































































































































Dimensions:



Code

No. Of
Cores

Conductor Size (mm2)

Stranding (mm)

Weight (kg/km)

Outside Diameter (mm)

Gland Size (mm)





   0315O

3

1.50

30/0.25

143.0

8.6

20/16





   0415O

4

1.50

30/0.25

170.0

9.3

20/16





   0325O

3

2.50

50/0.25

190.0

9.9

20/16





   0425O

4

2.50

50/0.25

240.0

10.8

20/16





   0525O

5

2.50

50/0.25

247.0

11.5

20S





   0340O

3

4.00

56/0.3

323.0

12.2

20S





   0440O

4

4.00

56/0.30

354.0

13.4

20S





   0540O

5

4.00

56/0.30

392.0

15.0

20.0





   0360O

3

6.00

84/0.30

343.0

13.4

20S





   0460O

4

6.00

84/0.30

458.0

14.6

20.0





   0560O

5

6.00

847/0.30

572.0

16.7

20.0



Note: 0315 Means 3 Core, 1.5mm2; O= LSZH


Conductor Resistance:


Nominal Cross Sectional Area (mm2)

Maximum Diameter Of
Wires In Conductor mm

Maximum Resistance Conductor
At 20




0.75

12.0

26.00




1.00

15.0

19.50




1.50

18.0

13.30




2.50

26.0

7.98




4.00

34.0

4.95




6.00

44.0

3.30





























Current Carrying Capacity:


Nominal Cross Sectional Area (mm2)

Current Carry Capacity
At 30 In Air Amps

Current Carry Capacity At 30
In Conduit (amps)




0.75

16.00

9.0




1

20.00

12.0




1.5

24.00

15.0




2.5

32.00

18.0




4

42.00

26.0




6

54.00

34.0





























Voltage Drop:


Nominal Cross Sectional Area (mm2)

Two Core Cable Dc
Mv/a/m

Single Phase Two Core Cable Ac
Mv/a/m

Three Phase 3 Or 4 Core Cable Ac
Mv/a/m





1

44

44

38.0




1.5

29

29

25.0




2.5

18

18

15.0




4

11

11

9.5




6

7.3

7.3

6.4




control cable  is a kind of power cable.

Tel
Email
Map