8723

8723

  • No.: 8723
  • Brand: AMPXL/OEM
  • Conductor Material: Tinned Copper
  • Conductor Diameter: 0.643mm
  • AWG: 22 AWG
  • Certification: CE, ROHS, UL, CCC
  • Insulation Material: Polypropylene
  • Insulation Diameter: 1.2 mm
  • Rip cord: NO
  • Jacket: PVC
  • Color: Customized
Close
Leave a Message We will call you back soon!
Email:ampxl@ampxl.com

Product Overview

Suitable Applications:

low voltage analog signals (4-20ma, 0-10v, ...); low voltage digital control (24v, …); line level audio; computer communication; panel wiring

Construction Details

Conductor

Element

Number of Element

Size

Stranding

Material

Pair(s)

2

22 AWG

7x30

TC - Tinned Copper

Insulation

Element

Material

Nom. Thickness

Nom. Insulation Diameter

Color Code

Pair(s)

PP - Polypropylene

0.009 in (0.23 mm)

0.046 in (1.2 mm)

Black & Red, Green & White

Inner Shield

Element

Shield Type

Material

Coverage

Drainwire Type

Notes

Pair(s)

Tape

Bi-Laminate (Alum+Poly)

100%

24 AWG (7x32) TC

foil-out tape on each pair, one drain wire

Outer Jacket

Material

Nom. Thickness

Nom. Diameter

PVC - Polyvinyl Chloride

0.020 in (0.51 mm)

0.160 in (4.06 mm)

 

Overall Cable Diameter (Nominal):

0.160 in (4.06 mm)

Electrical Characteristics

Electricals

Element

Nom. Conductor DCR

Nom. Inner Shield DCR

Nom. Capacitance Cond-to-Cond

Nom. Capacitance Cond-to-Other (Conds + Shield)

Nom. Characteristic Impedence

Nom. Velocity of Prop.

Max. Current

Pair(s)

18.2 Ohm/1000ft

18.38 Ohm/1000ft (60.30 Ohm/km)

33 pF/ft (110 pF/m)

62 pF/ft (200 pF/m)

52 Ohm

66%

2.8 Amps per Conductor at 25ºC

Voltage

UL Voltage Rating

300 V (CM)

Mechanical Characteristics

Temperature

UL Temperature

Operating

60°C

-20°C to +75°C

Bend Radius

Stationary Min.

Installation Min.

1.6 in (41 mm)

1.6 in (41 mm)

 

Max. Pull Tension:

42 lbs (19 kg)

 

Bulk Cable Weight:

17 lbs/1000ft

Standards and Compliance

Environmental Suitability:

Indoor

 

Flammability / Reaction to Fire:

IEC 60332-1-2

 

CPR Compliance:

CPR Euroclass: Eca; CPR UKCA Class: Eca

 

 

 

European Directive Compliance:

EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)


TAG: 8723
Tel
Email
Map